VX 55/50 - electric Pump VORTEX sewage three-phase
Flow rate up to 1000 l/min (60 m3/h). Head up to 22 m. Motor 4 Kw (5.5 HP).
The pump VX 55/50 is constructed of stainless steel and cast iron of considerable thickness ensures exceptional sturdiness, abrasion resistance and durability.
It is equipped with impeller of VORTEX type, and suitable for the drainage of water charges, sewage, sewage, water mixed with mud, sludge brightened and putrid.
Is suitable for installation in sewers, galleries, excavation, channels, underground car parks.
- Motor connection
- THREE-PHASE
- Motor power (HP)
- 5.5
- Absorption at 400V (A)
- 7
- Delivery port
- 2"
- Body Pump
- Cast iron
- Impeller
- Cast iron
- Number of impellers
- 1
- Motor shaft
- AISI 431 stainless steel
- Check valve
- no
- Degree of protection
- IP 68
- Flow rate min. (l./min.)
- 100
- Max flow (l./min.)
- 1000
- Min head (m.)
- 6.5
- Max head (m.)
- 25
- Cable length (m)
- 10
- Employments
- air conditioning systems, drying up, slightly dirty waters
- Liquid temperature max. (° C)
- +40°C
- Height (cm)
- 64.2
- Width (cm)
- 27.6
- Guarantee
- Two years
|
|
|
|
|
|
Bearings
Pump side motor bearing | 6306 ZZ C3 |
Opposite side engine bearing | 6304 ZZ C3 |
Tree holding
Type of seal | Double mechanical seal in oil chamber |
LM diameter | 25 |
LM fixed ring | Silicon carbide |
LM rotating ring | Graphite |
LM elastomer | NBR |
Shrinkage DN1=450 DN2=350 | ED560-25 |
LP diameter | 25 |
LP fixed ring | Silicon carbide |
LP rotating ring | Silicon carbide |
LP elastomer | NBR |
Materials
1.0 - Pump body | Cast iron GJL 200 EN 1561 |
3.0 - Impeller | Cast iron GJL 200 EN 1561 |
4.0 - Pump shaft | Stainless steel EN 1.4057 (AISI 431) |
6.0 - Motor holder | Stainless steel EN 1.4301 (AISI 304) |
6.1 - Engine cover | Cast iron GJL 200 EN 1561 |
7.0 - Lantern | Cast iron GJL 200 EN 1561 |
Compare with Similar Products
VX 55/50 - electric Pump VORTEX sewage three-phaseThis product Flow rate up to 1000 l/min (60 m3/h). Head up to 22 m. Motor 4 Kw (5.5 HP). | VX 40/50 - electric Pump VORTEX sewage three-phaseFlow rate up to 900 l/min (54 m3/h). Head up to 22 m. Engine 3 Kw (4 HP). | VX 40/65 - electric Pump VORTEX sewage three-phaseFlow rate up to 1200 l/min (72 m3/h). Head up to 16 m. Engine 3 Kw (4 HP). | VX 55/65 - electric Pump VORTEX sewage three-phaseFlow rate up to 1350 l/min (81 m3/h). Head up to 20 m. Motor 4 Kw (5.5 HP). | |
---|---|---|---|---|
Motor connection | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE |
Motor power (HP) | Motor power (HP) 5.5 | Motor power (HP) 4 | Motor power (HP) 4 | Motor power (HP) 5.5 |
Absorption at 400V (A) | Absorption at 400V (A) 7 | Absorption at 400V (A) 5.8 | Absorption at 400V (A) 6.2 | Absorption at 400V (A) 7.7 |
Delivery port | Delivery port 2" | Delivery port 2" | Delivery port 2" | Delivery port 2" |
Body Pump | Body Pump Cast iron | Body Pump Cast iron | Body Pump Cast iron | Body Pump Cast iron |
Impeller | Impeller Cast iron | Impeller Cast iron | Impeller Cast iron | Impeller Cast iron |
Number of impellers | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 |
Motor shaft | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel |
Check valve | Check valve no | Check valve no | Check valve no | Check valve no |
Degree of protection | Degree of protection IP 68 | Degree of protection IP 68 | Degree of protection IP 68 | Degree of protection IP 68 |
Flow rate min. (l./min.) | Flow rate min. (l./min.) 100 | Flow rate min. (l./min.) 100 | Flow rate min. (l./min.) 200 | Flow rate min. (l./min.) 200 |
Max flow (l./min.) | Max flow (l./min.) 1000 | Max flow (l./min.) 900 | Max flow (l./min.) 1200 | Max flow (l./min.) 1350 |
Min head (m.) | Min head (m.) 6.5 | Min head (m.) 5.5 | Min head (m.) 2.5 | Min head (m.) 3.7 |
Max head (m.) | Max head (m.) 25 | Max head (m.) 22 | Max head (m.) 17 | Max head (m.) 20.7 |
Cable length (m) | Cable length (m) 10 | Cable length (m) 10 | Cable length (m) 10 | Cable length (m) 10 |
Employments | Employments air conditioning systems, drying up, slightly dirty waters | Employments drainage, drying up, slightly dirty waters | Employments air conditioning systems, drying up, slightly dirty waters | Employments air conditioning systems, drying up, slightly dirty waters |
Liquid temperature max. (° C) | Liquid temperature max. (° C) +40°C | Liquid temperature max. (° C) 40 | Liquid temperature max. (° C) +40°C | Liquid temperature max. (° C) +40°C |
Height (cm) | Height (cm) 64.2 | Height (cm) 60.2 | Height (cm) 63 | Height (cm) 67 |
Width (cm) | Width (cm) 27.6 | Width (cm) 29.9 | Width (cm) 27.7 | Width (cm) 27.7 |
Weight kg) | Weight kg) -- | Weight kg) -- | Weight kg) 53.3 | Weight kg) 60 |
Guarantee | Guarantee Two years | Guarantee Two years | Guarantee Two years | Guarantee Two years |